| MBC Specifications |
|
|
 |
| Input: |
|
270 Vdc nominal (220-400 Vdc) |
| Input Power Characteristics: |
|
MIL-STD-704 meets normal and abnormal operation; MIL-STD-1275A with battery support |
| Temperature: |
|
Operating -55 to +85°C, Baseplate; -60 to +100°C, Storage |
| Humidity: |
|
MIL-Std-810L procedure 507.1 method IV |
| I/O Connection: |
|
PC board mount |
| |
| Dimensions: |
|
4.6 x 2.4 x .5 |
| Altitude: |
|
To 70,000 feet |
| Shock: |
|
MIL-S-501C, Grade A, type A, high impact shock |
| Vibration: |
|
MIL-E-5400, curve IVA, 5Hz to 2000 Hz |
| Salt Spray: |
|
MIL-STD-810C, method 509, procedure 1 |
 |
 |
| POL Specifications |
|
|
 |
| Input Range: |
|
11-14 Vdc |
| Output Voltage: |
|
1.0 Vdc - 3.3 Vdc @ up to 80 Amps |
| Load Regulation: |
|
Max deviation 1% for a load change of 20% to 80% of F.L. |
| Static Regulation: |
|
1% max combined line and load max |
| |
| Ripple & Noise P-P Max |
|
|
| (10 Hz-20MHz): |
|
2% of normal V out |
| Output Overshoot (typical): |
|
1% max of V out |
| Remote On/Off: |
|
Yes |
| Overload Protection: |
|
Limited to 120% max F.L., auto recover |
| Over Voltage Protection: |
|
Non shutdown type, trip point typical 130% V out |
| Efficiency typical: |
|
92% (3.3 V out) |
| |
| Temperature: |
|
Operating -55 to +85°C Ambient; -60 to +100°C Storage |
| Humidity: |
|
MIL-Std-810L procedure 507.1 method IV |
| I/O Connection: |
|
PC board mount |
| Dimensions: |
|
2.4 x 2.3 x .5 |
| Altitude: |
|
To 70,000 feet |
| Shock: |
|
MIL-S-501C, Grade A, type A, high impact shock |
| Vibration: |
|
MIL-E-5400, curve IVA, 5Hz to 2000 Hz |
| Salt Spray: |
|
MIL-STD-810C, method 509, procedure 1 |
 |
| |
|
Separate E.J.I. filter needed to meet MIL-STD-461 requirements |
 |